<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE ArticleSet PUBLIC "-//NLM//DTD PubMed 2.7//EN" "https://dtd.nlm.nih.gov/ncbi/pubmed/in/PubMed.dtd">
<ArticleSet>
<Article>
<Journal>
				<PublisherName>دانشگاه علوم پزشکی شهید بهشتی</PublisherName>
				<JournalTitle>دوماهنامه علمی - پژوهشی طب توانبخشی</JournalTitle>
				<Issn>2251-8401</Issn>
				<Volume>8</Volume>
				<Issue>3</Issue>
				<PubDate PubStatus="epublish">
					<Year>2019</Year>
					<Month>09</Month>
					<Day>23</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Relationship between the Double Corrected Consonant-Vowel Responses Score in Dichotic Consonant-Vowel Test and Amplitude and Latency of P300 Wave in Adults with Normal Hearing</ArticleTitle>
<VernacularTitle>بررسی ارتباط بین امتیازات جفت همخوان-واکه صحیح در آزمون همخوان- واکه دایکوتیک با دامنه و زمان نهفتگی موج P300 در بزرگسالان با شنوایی طبیعی</VernacularTitle>
			<FirstPage>241</FirstPage>
			<LastPage>249</LastPage>
			<ELocationID EIdType="pii">1100848</ELocationID>
			
<ELocationID EIdType="doi">10.22037/jrm.2019.110619.1417</ELocationID>
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>راحله</FirstName>
					<LastName>قاسمی پور</LastName>
<Affiliation>کمیته پژوهشی دانشجویی، کارشناس ارشد شنوایی شناسی، دانشکده علوم توانبخشی، دانشگاه علوم پزشکی شهید بهشتی، تهران ، ایران</Affiliation>

</Author>
<Author>
					<FirstName>لیلا</FirstName>
					<LastName>جلیلوند کریمی</LastName>
<Affiliation>مربی گروه شنوایی شتاسی، دانشکده علوم توانبخشی، دانشگاه علوم پزشکی شهید یهشتی، دانشجوی دکتری شنوایی شناسی،  دانشکده علوم توانبخشی، دانشگاه علوم پزشکی تهران تهران، ایران</Affiliation>
<Identifier Source="ORCID">0000-0003-3829-7658</Identifier>

</Author>
<Author>
					<FirstName>قاسم</FirstName>
					<LastName>محمدخانی</LastName>
<Affiliation>استادیار گروه شنوایی شناسی، دانشکده علوم توانبخشی، دانشگاه علوم پزشکی تهران، تهران، ایران</Affiliation>
<Identifier Source="ORCID">0000-0002-6685-4346</Identifier>

</Author>
<Author>
					<FirstName>پریسا</FirstName>
					<LastName>رسولی فرد</LastName>
<Affiliation>دانشجوی دکترا، گروه شنوایی شناسی، دانشکده علوم توانبخشی، دانشگاه علوم پزشکی ایران، تهران، ایران</Affiliation>

</Author>
<Author>
					<FirstName>علیرضا</FirstName>
					<LastName>اکبرزاده باغبان</LastName>
<Affiliation>استاد آمار زیستی، گروه علوم پایه، دانشکده علوم توانبخشی، دانشگاه علوم پزشکی شهید بهشتی، تهران، ایران</Affiliation>
<Identifier Source="ORCID">0000-0002-0961-1874</Identifier>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2018</Year>
					<Month>06</Month>
					<Day>05</Day>
				</PubDate>
			</History>
		<Abstract>&lt;strong&gt;Background and Aims:&lt;/strong&gt; There is little information on the double corrected consonant-vowel responses score in dichotic consonant-vowel test (DCV) and its nature is not entirely known. The only concept known is that it seems to be associated with auditory attention and concentration. Since P300 wave is one of the event-related potentials with attention as well as concentration involved in its formation, the present study was carried out to investigate the relationship between double corrected consonant-vowel responses score and the amplitude and latency of P300. &lt;br /&gt;&lt;strong&gt;Materials and Methods: &lt;/strong&gt;In the current non-interventional cross-sectional study, consonant-vowel dichotic test was performed to check double corrected consonant-vowel responses score and P300 auditory responses using odd-ball stimulation method and two tone burst stimuli on 37 participants with normal hearing. The participants were 18 to 30 year-old individuals (mean 21.46 years). To verify their right handedness, Edinburgh scale was used. The results were analyzed using Pearson&#039;s correlation coefficient in SPSS (v. 16). &lt;br /&gt;&lt;strong&gt;Results:&lt;/strong&gt; Significantpositive correlation was observed between double corrected consonant-vowel responses score in DCV test and P300 amplitude in both electrode positions of Cz and Fz (P &lt;0/01). Also, double corrected consonant-vowel responses score and P300 latency were observed to be significantly and positively correlated at Cz electrode position (P&lt;0/05).. However, there was no significant correlation between double corrected consonant-vowel responses score and P300 latency in Fz electrode position, which may be due to the Fz electrode position away from the source of the P300 wave. &lt;br /&gt;&lt;strong&gt;Conclusion:&lt;/strong&gt; Since the P300 amplitude is associated with attention and P300 latency is associated with information processing speed, it seems that double corrected consonant-vowel responses score is associated with attention and information processing speed. So, audiologists must consider the individual’s attention when interpreting the results</Abstract>
			<OtherAbstract Language="FA">مقدمه و اهداف&lt;br /&gt; اطلاعات کمی در مورد امتیاز جفت همخوان-واکه صحیح در آزمون همخوان-واکه دایکوتیک (DCV) وجود دارد و ماهیت آن بدرستی روشن نیست و به نظر می رسد که با توجه و تمرکز شنیداری در ارتباط باشد.از آنجا که موج P300 یکی از پتانسیل های وابسته به رخدادی است که در شکل گیری آن توجه و تمرکز نیز دخالت دارد،لذا این مطالعه با هدف بررسی رابطه بین امتیاز جفت همخوان-واکه صحیح با دامنه و زمان نهفتگی موج P300 انجام شد.&lt;br /&gt; روش پژوهش&lt;br /&gt; در این پژوهش مقطعی و غیر مداخله ای،توصیفی-تحلیلی، آزمون DCV، جهت بررسی امتیازات جفت همخوان-واکه صحیح و پاسخ P300شنوایی به روش تحریک متفاوت با استفاده از دو محرک تن برست،روی 37 فرد با شنوایی طبیعی در محدوده سنی 18 تا 30 سال( میانگین سنی 21/46سال)انجام شد.یافته ها بر اساس آزمون ضریب همبستگی پیرسون و نرم افزار SPSS16 ، مورد تجزیه و  تحلیل قرار گرفت.&lt;br /&gt; یافته ها&lt;br /&gt; بین امتیاز جفت همخوان-واکه صحیح در آزمونDCV  با دامنه موج P300 در جایگاه الکترودی Cz و Fz همبستگی مثبت و معنا داری مشاهده شد (P&lt;0/01). بین امتیاز جفت همخوان-واکه صحیح با زمان نهفتگی موج P300 در جایگاه الکترودی Cz همبستگی مثبت و معنی دار مشاهده شد(P&lt;0/05). اما بین امتیاز جفت همخوان-واکه صحیح با زمان نهفتگی موج P300 در جایگاه الکترودی Fz همبستگی معناداری مشاهده نشد،که احتمالا به علت دوری جایگاه الکترودی Fz از منبع تولید موج P300است.&lt;br /&gt; &lt;strong&gt;نتیجه&lt;/strong&gt; گیری&lt;br /&gt; از آنجا که دامنه موج P300 با  توجه و زمان نهفتگی موج P300 با سرعت پردازش اطلاعات در ارتباط  است،به نظر می رسد که امتیاز جفت همخوان-واکه صحیح با توجه و سرعت پردازش اطلاعات، ارتباط داشته باشد. بنابراین شنوایی شناس باید در تفسیر نتایج،توجه فرد مورد آزمون را در نظر گیرد.</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">ظرفیت شنوایی</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">پتانسیل وابسته به رخداد</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">توجه شنیداری</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://medrehab.sbmu.ac.ir/article_1100848_29d884080e57c2e9e8c814a59ae32059.pdf</ArchiveCopySource>
</Article>
</ArticleSet>
