Reliability of Synchronization Software in Measuring Tibialis Anterior Muscle Structure and Force: An Ultrasonographic Study

Document Type : Original article

Authors

1 Assistant Professor of Physical Therapy, School of Rehabilitation, Shahid Beheshti University of Medical Sciences,Tehran,Iran

2 Student Research Committee. MSc Student of Physical Therapy, School of Rehabilitation, Shahid Beheshti University of Medical Sciences,Tehran, Iran.

3 Professor of Physical Therapy, School of Rehabilitation, Shahid Beheshti University of Medical Sciences,Tehran, Iran

4 Professor of Biostatistics, School of Rehabilitation, Shahid Beheshti University of Medical Sciences,Tehran, Iran

Abstract

Background and Aims: The present study was conducted to evaluate the intra-rater reliability of synchronization software so as to measure the Tibialis Anterior Muscle (TAM) structural parameters and force during contraction in healthy-nonathletes using ultrasonography and dynamometery in a synchronized way. This software was used in order to increase the ability of recording of pictures and data from ultrasonography and dynamometry synchronizingly.
Materials and Methods: In the present cross-sectional study, the reliability of measuring the TAM structural parameters and force with the synchronization software was evaluated on 15 healthy non-athletes, aged 18 -35 years, with BMI (23±1/8). An Ultrasonography B mode and a Dynamometer were used during three states of contractions: maximum voluntary contraction, electrical stimulation, and the combination of both in healthy non-athlete individuals. The Pennation Angle (PA), Fascicle Length (FL), and Muscle Thickness (MT) and Force (F) of TAM were measured in three states of contraction and then the measurements were repeated one hour later in order to determine intra-rater reliability. Interclass Correlation Coefficient (ICC), Standard Error of Measurement (SEM), and Smallest Detectable Difference (SDD) were used to evaluate the relative and absolute reliability, respectively.
Results: The synchronization software was found to be highly reliable in measuring the TAM structures and force in three states of contraction (MVC), (ES), and (MVC+ES) in healthy-non athletes. The ICCs for muscle thickness of TAM were 80%, 98%, 93%, respectively. For PA, the ICCs were 88%, 77%, and 75% respectively and ICCs for FL force in the three states of contraction (MVC), (ES) and (MVC+ES) were 95%, 97%, and 91%, respectively. Also, the ICCs for F in three states of contraction (MVC), (ES), and (MVC+ES) were 82%, 97%, and 91%, respectively.
Conclusion: Ultrasonographic measurement and dynamometry of TAM using synchronization software has proved to be reliable for measuring the structural parameters of TAM and force in healthy-non athletes in three states of contraction in a synchronized manner.

Keywords

Main Subjects


1. Rezasoltani A, Ylinen J, Vihko V. Isometric cervical extension force and dimensions of semispinalis capitis muscle. Journal of rehabilitation research and development. 2002;39(3):423-8.##
2. Hodges P, Pengel L, Herbert R, Gandevia S. Measurement of muscle contraction with ultrasound imaging. Muscle & nerve. 2003;27(6):682-92. ##
3. Beazell JR, Grindstaff TL, Hart JM, Magrum EM, Cullaty M, Shen FH. Changes in lateral abdominal muscle thickness during an abdominal drawing-in maneuver in individuals with and without low back pain. Research in Sports Medicine. 2011;19(4):271-82. ##
4. Noorkoiv M, Stavnsbo A, Aagaard P, Blazevich AJ. In vivo assessment of muscle fascicle length by extended field-of-view ultrasonography. Journal of applied physiology. 2010;109(6):1974-9. ##
5. Loram ID, Maganaris CN, Lakie M. Use of ultrasound to make noninvasive in vivo measurement of continuous changes in human muscle contractile length. Journal of applied physiology. 2006;100(4):1311-23. ##
6. Adsuar JC, Olivares PR, Parraca JA, Hernández-Mocholí MA, Gusi N. Applicability and test-retest reliability of isokinetic shoulder abduction and adduction in women fibromyalgia patients. Archives of physical medicine and rehabilitation. 2013;94(3):444-50. ##
7. Arimi SA, Rezasoltani A, Sakhaei SY, Tabatabaei SM, Khalkhali M. Reliability of Ultrasonographic Measurement of Cervical Multifidus Muscle Dimensions during Isometric Contraction of Neck Muscles. Rehabilitation Medicine. 2013;1(2). ##
8. Cadogan A, Laslett M, Hing W, McNair P, Williams M. Interexaminer reliability of orthopaedic special tests used in the assessment of shoulder pain. Manual therapy. 2011;16(2):131-5. ##
9. Cagnie B, Derese E, Vandamme L, Verstraete K, Cambier D, Danneels L. Validity and reliability of ultrasonography for the longus colli in asymptomatic subjects. Manual therapy. 2009;14(4):421-6. ##
10. Khalkhali M, Tabatabaei SM, Sakhaei SY, Rezasoltani A, Arimi SA. Reliability of Ultrasonographic Measurement of Cervical Multifidus Muscle Dimensions during Isometric Contraction of Neck Muscles. 2012. ##
11. Koppenhaver SL, Hebert JJ, Fritz JM, Parent EC, Teyhen DS, Magel JS. Reliability of rehabilitative ultrasound imaging of the transversus abdominis and lumbar multifidus muscles. Archives of physical medicine and rehabilitation. 2009;90(1):87-94. ##
12. Kristjansson E. Reliability of ultrasonography for the cervical multifidus muscle in asymptomatic and symptomatic subjects. Manual therapy. 2004;9(2):83-8. ##
13. Lin Y-J, Chai H-M, Wang S-F. Reliability of thickness measurements of the dorsal muscles of the upper cervical spine: an ultrasonographic study. journal of orthopaedic & sports physical therapy. 2009;39(12):850-7. ##
14. Weir JP. Quantifying test-retest reliability using the intraclass correlation coefficient and the SEM. The Journal of Strength & Conditioning Research. 2005;19(1):231-40. ##
15. Peolsson AL, Peolsson MN, Jull GA. Cervical muscle activity during loaded arm lifts in patients 10 years postsurgery for cervical disc disease. Journal of manipulative and physiological therapeutics. 2013;36(5):292-9. ##
16. Lee J-P, Tseng W-YI, Shau Y-W, Wang C-L, Wang H-K, Wang S-F. Measurement of segmental cervical multifidus contraction by ultrasonography in asymptomatic adults. Manual therapy. 2007;12(3):286-94. ##
17. Manal K, Roberts DP, Buchanan TS. Optimal pennation angle of the primary ankle plantar and dorsiflexors: variations with sex, contraction intensity, and limb. Journal of applied biomechanics. 2006;22(4):255. ##
18. Zhou Y, Li J-Z, Zhou G, Zheng Y-P. Dynamic measurement of pennation angle of gastrocnemius muscles during contractions based on ultrasound imaging. Biomed Eng Online. 2012;11:63. ##
19. Ruiz-Muñoz M, Cuesta-Vargas AI. Electromyography and sonomyography analysis of the tibialis anterior: a cross sectional study. J Foot Ankle Res. 2014;7:11. ##
20. Doucet BM, Lam A, Griffin L. Neuromuscular electrical stimulation for skeletal muscle function. The Yale journal of biology and medicine. 2012;85(2):201. ##
21. Ruiz-Muñoz M, Cuesta-Vargas AI. Electromyography and sonomyography analysis of the tibialis anterior: a cross sectional study. Journal of foot and ankle research. 2014;7(1):11. ##
22. Lieber RL. Skeletal muscle structure, function, and plasticity: Lippincott Williams & Wilkins; 2002. ##
23. Pasquet B, Carpentier A, Duchateau J. Change in muscle fascicle length influences the recruitment and discharge rate of motor units during isometric contractions. Journal of neurophysiology. 2005;94(5):3126-33. ##
24. Reeves ND, Narici MV. Behavior of human muscle fascicles during shortening and lengthening contractions in vivo. Journal of Applied Physiology. 2003;95(3):1090-6. ##
25. Çelik D, Dirican A, Baltaci G. Intrarater reliability of assessing strength of the shoulder and scapular muscles. J Sport Rehabil. 2012;29:1-5. ##
26. Carter R, Lubinsky J, Domholdt E. Rehabilitation research: principles and applications: Elsevier Health Sciences; 2013. ##
27. Kwah LK, Pinto RZ, Diong J, Herbert RD. Reliability and validity of ultrasound measurements of muscle fascicle length and pennation in humans: a systematic review. Journal of Applied Physiology. 2013;114(6):761-9##
28. Brancaccio P, Limongelli FM, D’Aponte A, Narici M, Maffulli N. Changes in skeletal muscle architecture following a cycloergometer test to exhaustion in athletes. Journal of Science and Medicine in Sport. 2008;11(6):538-41. ##