Comparison of Evaluation of Belin-Ambrosio indices and Rabinowitz criteria in refractive surgery candidates

Document Type : Original article

Authors

1 1. MSc. In Optometry, optometry department of rehabilitation faculty, Tehran University of Medical Science.

2 2. Ophthalmologist, Razi Eye Clinic, Tehran, Iran.

3 3. Associate professor of optometry department of rehabilitation faculty, Tehran University of Medical Science.

Abstract

Background and Aim: Meticulous preoperative screening is one of the key factors that contribute to success in refractive surgery. The purpose of this study was to evaluate the Belin-Ambrosio and Rabinowitz indices as screening methods before refractive surgery to distinguish keratoconus suspects from normal patients.
Materials and Methods: In this descriptive study, Pentacam data of 30 normal eyes (N) and 19 abnormal eyes with suspect keratoconus (KCS) were analyzed. Belin-Ambrosio and Rabinowitz indices were tested. Using SPSS Statistical Software (version17), an Independent T test was performed for statistical analysis.
Results: The mean age of patients was 25.51±3.97 years and the mean of myopia was
 -2.87±3.97 and the mean of astigmatism was -1.25±1.08 diopters.All tested variables had significant differences between N and KCS (Independent T-test, p< 0.001) except I-S value (p=0.22). The BAD-D and BAD-Dp had the greatest differences from Cutoff value.
Conclusion: The Belin-Ambrosio indices provide additional information in diagnosis of suspect keratoconus compared to Rabinowitz criteria. In this study, the BAD-D and BAD-Dp were better approaches for detecting keratoconus.
Key Words: Belin-Ambrosio indices, Rabinowitz criteria, Keratoconus, Pentacam

Keywords


  1. Schweitzer C, Mahmoud AM, Maurice-Tison S, Kerautret J.  Screening of Forme Fruste Keratoconus with the Ocular Response Analyzer .J IOVS 2010; 51(5):2403-2410.
  2. Ambrósio Jr R. Simplifying Ectasia Screening with Pentacam Corneal Tomography. J Highlights of Ophthalmology 2010; 38(3):12-20.
  3. Randleman JB, Woodward M, Lynn MJ, Stulting RD. Risk Assessment for Ectasia after Corneal Refractive Surgery. J Ophtha2008; 115(1):37-50.
  4. Moshirfar M, Edmonds JN, Behunin NL, Christiansen SM. Corneal biomechanics in iatrogenic ectasia and keratoconus: A review of the literature. Oman J Ophthalmol2013; 6(1): 12–17.
  5. Ambrósio R Jr, Klyce SD, Wilson SE. Corneal Topographic and Pachymetric Screening of Keratorefractive Patients. J Refract Surg2003; 19(1):24-9.
  6. Ambrosio R Jr, Correia FF, Ramos I, Valbon BF , Lopes B , Jardim D , et al . Enhanced Screening for Ectasia Susceptibility Among Refractive Candidates: The Role of Corneal Tomography and Biomechanics. J Curr Ophthalmol Rep 2013; 1(1):28–38.
  7. Correia FF, Ramos I, Lopes B, Salomao MQ, Luz A, Correa RO, Belin MW, Ambrósio R Jr. Topometric and Tomographic Indices for the Diagnosis of Keratoconus. Int J Kerat ECT Cor Dis 2012; 1(2):92-99.
  8. Swartz T, Marten L, Wang M. Measuring the cornea: the latest developments in corneal topography. J Curr Opin Ophthalmol 2007; 18(4):325–333.
  9. Buhren J, Kook D, Yoon G, Kohnen T. Detection of Subclinical Keratoconus by Using Corneal Anterior and Posterior Surface Aberrations and Thickness Spatial Profiles. J IOVS2010; 51(7): 3424-3432.
  10. Belin MW, Khachikian SS, Ambrosio R Jr. Keratoconus/Ectasia Detection with a modified (Enhanced) Refractive Surface Belin/Ambrosio Enhanced Ectasia Display III. In:  Belin MW, Khachikian SS, Ambrosio R Jr, editors.Elevation Based Corneal Tomography. Second ed. JP Medical Ltd; 2012. P. 93-104.
  11. Belin MW, Khachikian SS, Ambrosio R Jr. Keratoconus / Ectasia Detection with the Oculus Pentacam: Belin / Ambrosio Enhanced Ectasia Display. J Highlights Ophthalmol.  2007; 35(6):5-12.
  12. Wang Li, Koch DD, Ang RT, Yildirim R. Corneal topography and Lasik applications. In:   Azar DT, Koch DD, editors. Lasik: Fundamentals surgical Techniques and complications .CRC Press; 2002. p. 111-138.
  13. Ambrosio R Jr, Ramos I, Correia FF, Belin MW. Tomographic screening for ectasia susceptibility - Analysis must go beyond corneal curvature and central thickness. J Cataract Refract Surg Today Eur 2012; 20(5):20-26

Ambrosio R Jr, Alonso RS, Luz A, Coca Velarde LG. Corneal-thickness spatial profile and corneal-volume distribution: Tomographic indices to detect keratoconus. J Cataract Refract Surg 2006; 32(11):1851-9.

Volume 3, Issue 3 - Serial Number 3
September and October 2014
Pages 19-25
  • Receive Date: 04 November 2013
  • Revise Date: 09 April 2014
  • Accept Date: 06 June 2014
  • First Publish Date: 23 September 2014